ztta/roll_extension_dia

Parameter

ztta/roll_extension_dia

Short text

Quota in extended memory for dialog processes

Parameter Description

This parameter specifies the maximum amount of extended memory to be occupied by dialog work processes. Previously, non-dialog processes (BTC, UPD, UP2, SPO, etc.) and dialog processes were handled in the same way. You could not allocate separate EM quotas for dialog users and background processing users.

The new profile parameters ztta/roll_extension_dia and ztta/roll_extension_nondia allow you to set EM quotas that differentiate between the work process types.

To remain compatible with the “old” ztta/roll_extension parameter, the following rule applies:

If ztta/roll_extension_dia or ztta/roll_extension_nondia are not set (DEFAULT.PFL or instance profile), the value in ztta/roll_extension (old procedure) applies for ALL work process types. If, on the other hand, ztta/roll_extension_(non)dia is set, the value in ztta/roll_extension is overwritten for the work process type in question.

Application Area

Extended Memory

Parameter Unit

Bytes

Default Value

2 000 000 000

Who is permitted to make changes?

Administrator

Operating System Restrictions

None

Database System Restrictions

None

Are other parameters affected or dependent?

ztta/roll_extension
ztta/roll_extension_nondia

See also:
ABAP/HEAP_AREA_DIA
ABAP/HEAP_AREA_NONDIA

Values allowed

From 20 000 000 to 64 000 000 000