Parameter
gw/netstat_once
Short text
Get own IP addresses only during startup
Parameter Description
When you start up the gateway, all of your own IP addresses are determined with the ‘netstat’ command and saved internally. This is necessary to be able to establish whether a program must be started locally or remotely.
There are high-availability solutions in which IP addresses can wander from one host to another. That is, the entries that are read when the gateway was started may no longer be valid. In this case, the current configuration must always be read when performing the test for a local IP address. To activate this mechanism, this profile parameter must be set to 0.
A default value of 1 means that the configuration is read only once during start up.
Application Area
Gateway
Parameter Unit
Boolean value (0/1)
Default Value
1
Who is permitted to make changes?
Customer
Operating System Restrictions
None
Database System Restrictions
None
Are other parameters affected or dependent?
gw/netstat
gw/alternative_hostnames
Values allowed
0 / 1