Parameter
rdisp/shutdown/auto_logout
Short text
Max. lazy time for online users during shutdown
Parameter Description
This parameter defines how long dialog users can be inactive for during the kernel shutdown before they are automatically logged out. If you specify a value > 0, the maximum waiting time is calculated from the minimum values of parameters rdisp/gui_auto_logout and rdisp/shutdown/auto_logout.
The value 0 means that a timeout is not triggered when waiting.
Application Area
Dispatcher
Parameter Unit
You can make a specification with or without a time unit. If you do not specify a time unit, seconds is used as the unit. Otherwise, you can specify M for minutes, H for hours, or D for day. There can be spaces between the value and the unit.
Examples
300 300 Seconds
2 M 2 Minutes
3H 3 Hours
Default Value
300
Who is permitted to make changes?
Customer
Operating System Restrictions
None
Database System Restrictions
None
Are other parameters affected or dependent?
rdisp/shutdown/load_balance_wait_time
rdisp/shutdown/disable_login
rdisp/shutdown/trigger_timeout
rdisp/shutdown/idle_wp_timeout
rdisp/shutdown/longrunner_timeout
rdisp/shutdown/max_time
rdisp/shutdown/j2ee_timeout
Values allowed
n [unit] where
• n >= 0
• Unit = S | M | H | D