rdisp/shutdown/idle_wp_timeout

Parameter

rdisp/shutdown/idle_wp_timeout

Short text

Max. time to wait for idle work processes during shutdown

Parameter Description

This parameter defines how long the kernel shutdown waits for all work processes to be in the “waiting” state.

The value 0 means that a timeout is not triggered when waiting.

Application Area

Dispatcher

Parameter Unit

You can make a specification with or without a time unit. If you do not specify a time unit, seconds is used as the unit. Otherwise, you can specify M for minutes, H for hours, or D for day. There can be spaces between the value and the unit.

Examples

300 300 Seconds

2 M 2 Minutes

3H 3 Hours

Default Value

60 seconds

Who is permitted to make changes?

Customer

Operating System Restrictions

None

Database System Restrictions

None

Are other parameters affected or dependent?

rdisp/shutdown/load_balance_wait_time

rdisp/shutdown/disable_login

rdisp/shutdown/auto_logout

rdisp/shutdown/trigger_timeout

rdisp/shutdown/longrunner_timeout

rdisp/shutdown/max_time

rdisp/shutdown/j2ee_timeout

Values allowed

n [unit] where

• n >= 0
• Unit = S | M | H | D