Parameter Description
This is a vector parameter in the format <parameter name>_<index>. The recognized index range is 0 to 20. Gaps in the index are permitted.
Every parameter value starts a program. The index number gives the order in which the programs are to be started.
The first word of a value must be either “immediate” or “local”. First, all programs flagged with “immediate” are started synchronously, one after the other. When this is complete, all those programs flagged with “local” are started asynchronously. “immediate” is usually used to start programs, such as sapcpe, which prepare the actual instance start (for example, replicate kernel). “local” is used to start the actual instance programs, such as disp+work.
The same index number must not be used for both Start_Program and Restart_Program entries at the same time.
Application Area
System
Parameter Unit
None
Default Value
None
Who is permitted to make changes?
Customer
Operating System Restrictions
None
Database System Restrictions
None