Archive writing and deletion are different operations. If an operator should monitor or prepare archiving but must not delete application data, review the authorization design rather than removing SARA from everybody’s menu.
Check the role
In PFCG inspect S_ARCHIVE for the specific archiving object and activity. Use the object documentation in SU21 and the application archiving guide to determine the required activities. Check the job execution user as well as the interactive operator, because archive programs often run in background.
Use STAUTHTRACE in a test system to verify which checks the write and delete functions actually perform. Test the intended allowed and denied operations separately. Ensure the role cannot bypass the restriction through direct report or background-job execution. Never run a productive deletion job simply to test an authorization change.
Reference
SAP Note: 3785850
SAP Help: Documentation