Parameter
rdisp/keepalive
Short text
Timer to check unused SAP GUI connections
Parameter Description
Specifies the maximum time in seconds after which the dispatcher checks an SAP GUI connection in which there has been no data transfer during this period. If the SAP GUI does not respond within the period defined by rdisp/keepalive_timeout, the dispatcher closes the connection.
Value 0 deactivates this check.
Application Area
Dispatcher
Parameter Unit
You can specify the value with or without a time unit. If you do not specify a time unit, seconds is used as the unit. Otherwise, you can specify M for minutes, H for hours, or D for day. There can be spaces between the value and the unit.
Examples
300, 300 Seconds
2 M, 2 Minutes
3H, 3 Hours
Default Value
1200 seconds
Who is permitted to make changes?
Customer
Operating System Restrictions
None
Database System Restrictions
None
Are other parameters affected or dependent?
rdisp/keepalive_timeout
Values allowed
n [unit] where
• n >= 0
• Unit = S | M | H | D