rdisp/max_dynamic_wp_alive_time

Parameter

rdisp/max_dynamic_wp_alive_time

Short text

Maximal alive time for idle dynamic workproesses

Parameter Description

If all processes of a type (for example, DIA) of a server are in state ‘Stop’ and dynamic work processes have been configured, the Dispatcher starts work processes to resolve any possible blackages. These processes can then be used for a specific time. The parameter defines the time period from which dynamic processes that are no longer are then ended again.

Application Area

Dispatcher

Parameter Unit

You can make a specification with or without a time unit. If you do not specify a time unit, seconds is used as the unit. Otherwise, you can specify M for minutes, H for hours, or D for day. There can be spaces between the value and the unit.

Examples

300 300 Seconds

2 M 2 Minutes

3H 3 Hours

Default Value

300

Who is permitted to make changes?

Customer

Operating System Restrictions

None

Database System Restrictions

None

Values allowed

n [unit] where

• n >= 0
• Unit = S | M | H | D