rdisp/max_sleep

Parameter

rdisp/max_sleep

Short text

Wakeup time for dispatcher

Parameter Description

Normally the dispatcher becomes active as soon as there is a request in its request queue, or input needs to be read from an SAP GUI or from the message server. However, it also becomes active after the period configured by the parameter rdisp/max_sleep to execute periodic tasks, for example.

Application Area

Dispatcher

Parameter Unit

You can specify the value with or without a time unit. If you do not specify a time unit, seconds is used as the unit. Otherwise, you can specify M for minutes, H for hours, or D for day. There can be spaces between the value and the unit.

Examples

300 300 Seconds

2 M 2 Minutes

3H 3 Hours

Default Value

20

Who is permitted to make changes?

Customer

Operating System Restrictions

None

Database System Restrictions

None

Are other parameters affected or dependent?

None

Values allowed

n [unit] where

• n >= 0
• Unit = S | M | H | D