Parameter
rdisp/max_sleep
Short text
Wakeup time for dispatcher
Parameter Description
Normally the dispatcher becomes active as soon as there is a request in its request queue, or input needs to be read from an SAP GUI or from the message server. However, it also becomes active after the period configured by the parameter rdisp/max_sleep to execute periodic tasks, for example.
Application Area
Dispatcher
Parameter Unit
You can specify the value with or without a time unit. If you do not specify a time unit, seconds is used as the unit. Otherwise, you can specify M for minutes, H for hours, or D for day. There can be spaces between the value and the unit.
Examples
300 300 Seconds
2 M 2 Minutes
3H 3 Hours
Default Value
20
Who is permitted to make changes?
Customer
Operating System Restrictions
None
Database System Restrictions
None
Are other parameters affected or dependent?
None
Values allowed
n [unit] where
• n >= 0
• Unit = S | M | H | D