Parameter
icm/wp_roll_timeout
Short text
Maximum work process blocking time
Parameter Description
You can use this parameter to specify the maximum length of time that a work process can run when reading data using the ICM, without being rolled out. With slow network connections and large quantities of data, the read length can become very long (> 600 seconds).
Note: This parameter must be set to a value smaller than rdisp/max_wprun_time , since the processing in the work process is terminated anyway after this length of time.
Application Area
Internet Communication Manager
Parameter Unit
Seconds
Default Value
15
Who is permitted to make changes?
System administrator
Operating System Restrictions
none
Database System Restrictions
None
Are other parameters affected or dependent?
rdisp/max_wprun_time