icm/wp_roll_timeout

Parameter

icm/wp_roll_timeout

Short text

Maximum work process blocking time

Parameter Description

You can use this parameter to specify the maximum length of time that a work process can run when reading data using the ICM, without being rolled out. With slow network connections and large quantities of data, the read length can become very long (> 600 seconds).

Note: This parameter must be set to a value smaller than rdisp/max_wprun_time , since the processing in the work process is terminated anyway after this length of time.

Application Area

Internet Communication Manager

Parameter Unit

Seconds

Default Value

15

Who is permitted to make changes?

System administrator

Operating System Restrictions

none

Database System Restrictions

None

Are other parameters affected or dependent?

rdisp/max_wprun_time