rdisp/http_min_wait_dia_wp

Parameter

rdisp/http_min_wait_dia_wp

Short text

Number of waiting dialog work processes

Parameter Description

Number of dialog work processes that should remain free for other users and are therefore not available for plug-in requests (HTTP(S) SMPT). If no dialog work processes are available for plug-in requests, no further resources are returned to the caller, since the server is to be protected against overloads. The absolute number of dialog work processes is specified by the parameter rdisp/wp_no_dia.

Example

There are 10 dialog WPs, rdisp/http_min_wait_dia_wp = 4. If the dispatcher receives an HTTP request from the ICM for processing and there are currently four dialog work processes free, the request is placed in the queue, and only processed once at least five dialog work processes are free. There is a similar procedure for RFC calls, see rdisp/rfc_min_wait_dia_wp .

Application Area

Dispatcher

Parameter Unit

Number of dialog work processes

Default Value

1

Who is permitted to make changes?

The customer

Operating System Restrictions

None

Database System Restrictions

None

Are other parameters affected or dependent?

rdisp/wp_no_dia
rdisp/http_check

Values allowed

0 – (Number of dialog WPs – 1)

You May Also Like