Parameter
rdisp/http_min_wait_dia_wp
Short text
Number of waiting dialog work processes
Parameter Description
Number of dialog work processes that should remain free for other users and are therefore not available for plug-in requests (HTTP(S) SMPT). If no dialog work processes are available for plug-in requests, no further resources are returned to the caller, since the server is to be protected against overloads. The absolute number of dialog work processes is specified by the parameter rdisp/wp_no_dia.
Example
There are 10 dialog WPs, rdisp/http_min_wait_dia_wp = 4. If the dispatcher receives an HTTP request from the ICM for processing and there are currently four dialog work processes free, the request is placed in the queue, and only processed once at least five dialog work processes are free. There is a similar procedure for RFC calls, see rdisp/rfc_min_wait_dia_wp .
Application Area
Dispatcher
Parameter Unit
Number of dialog work processes
Default Value
1
Who is permitted to make changes?
The customer
Operating System Restrictions
None
Database System Restrictions
None
Are other parameters affected or dependent?
rdisp/wp_no_dia
rdisp/http_check
Values allowed
0 – (Number of dialog WPs – 1)