Core Dump in DiagoTabFocusColumn()

Symptom

If the focus is set on an invisible cell of a table control, a core dump occurs in the C function DiagoTabFocusColumn(). This problem occurs in Customizing option “Maintain Allocation Structures”, for example. A SYSTEM_CORE_DUMPED dump is triggered with the error message “Process terminated by signal 0”. The termination occurs in program SAPL0C5D, event SYSTEM-EXIT. The main program is SAPLSETB.

Solution

You need to apply a kernel patch to eliminate the error. Refer to SAP Note 1525687, 1555682.