rdisp/autoabaptime

Parameter

rdisp/autoabaptime

Short text

Specifies the time cycle in seconds for program SAPMSSY6 (AUTOABAP)

Parameter Description

This parameter controls the time internal in which the SAPMSSY6 (screen 1100) is executed. A value of 0 deactivates the automatic execution. With a value of n > 0, the program is periodically executed in the background every n seconds (see Unit below).

Application Area

Dispatcher and task handler

Parameter Unit

You can make a specification with or without a time unit. If you do not specify a time unit, seconds is used as the unit. Otherwise, you can specify M for minutes, H for hours, or D for day. There can be spaces between the value and the unit.

Examples

300, 300 Seconds

2M, 2 Minutes

3H, 3 Hours

Default Value

300 seconds

Who is permitted to make changes?

Customer

Operating System Restrictions

None

Database System Restrictions

None

Are other parameters affected or dependent?

rdisp/autoabapuser

Values allowed

n [unit] where

• n >= 0
• Unit = S | M | H | D