Parameter
rdisp/autothtime
Short text
Time cycle for periodic taskhandler checks
Parameter Description
rdisp/autothtime defines the time interval for the checks performed periodically in the taskhandler. These include,
• The automatic resetting of the trace files
• Auto-logout for external plug-ins (HTTP, and so on)
Application Area
Taskhandler
Parameter Unit
You can make a specification with or without a time unit. If you do not specify a time unit, seconds is used as the unit. Otherwise, you can specify M for minutes, H for hours, or D for day. There can be spaces between the value and the unit.
Examples
300, 300 Seconds
2M, 2 Minutes
3H, 3 Hours
Default Value
60
Who is permitted to make changes?
Customer
Operating System Restrictions
None
Database System Restrictions
None
Are other parameters affected or dependent?
rdisp/TRACE_LOGGING
rdisp/plugin_auto_logout
Values allowed
n [unit] where
• n > 0
• Unit = S | M | H | D