Parameter
rdisp/ext_timer_stop_delay
Short text
Time to wait before an unsed VMC timer process should be terminated
Parameter Description
The VMC (Virtual Machine Container) offers the optio to record the process flow of applications using time sampling. The affected VMs must be requested to write the necessary data during execution by events. Since these events must be triggered in a finely-granulated way, this takes place by an external process that is started before the recording begins. After completing a measurement, the process is then ended again with a certain delay.
Application Area
VMC
Parameter Unit
You can make a specification with or without a time unit. If you do not specify a time unit, seconds is used as the unit. Otherwise, you can specify M for minutes, H for hours, or D for day. There can be spaces between the value and the unit.
Examples
300, 300 Seconds
2 M, 2 Minutes
3H, 3 Hours
Default Value
300
Who is permitted to make changes?
Customer
Operating System Restrictions
None
Database System Restrictions
None
Values allowed
n [unit] where
• n >= 0
• Unit = S | M | H | D