Parameter
rdisp/j2ee_timeout
Short text
Reconnect timeout for j2ee server
Parameter Description
Within this time span, the J2EE Engine must log on to the dispatcher. If not, it is assumed that the J2EE Engine had problems starting and it is started again. You can determine the number of incorrect start attempts using parameter rdisp/j2ee_error. If this number of start attempts failed, this deactivates the starting of the J2EE Engine. By dynamically switching using parameter rdisp/j2ee_start, you can reactivate the restart.
Application Area
Dispatcher/J2EE Engine
Parameter Unit
You can specify the value with or without a time unit. If you do not specify a time unit, seconds is used as the unit. Otherwise M can be specified for minute or H for hour. There can be spaces between the value and the unit.
Examples
• 1. 300 seconds
• 2. M 2 minutes
• 3. H 3 hours
Default Value
60
Who is permitted to make changes?
Customer
Operating System Restrictions
None
Database System Restrictions
None
Are other parameters affected or dependent?
rdisp/j2ee_start
rdisp/j2ee_error
Values allowed
Character string