rdisp/TRACE_RESOLUTION

Parameter

rdisp/TRACE_RESOLUTION

Short text

Maximum number of time stamps in trace file per second

Parameter Description

You can use this parameter to control the frequency of the time stamp in the trace files. It specifies how many times per second a time stamp is to be written. The default value for this parameter is 1, which means that there is (at least) one second between the time stamps. If the parameter has the value 10, there is (at least) 100ms between the time stamps.

The value 0 deactivates the writing of time stamps.

With a parameter value > 0, the milliseconds of the time stamp are displayed in the following format:

“Fri Sep 3 14:47:54:433 2004”

Application Area

System

Default Value

1

Who is permitted to make changes?

Customer

Operating System Restrictions

None

Database System Restrictions

None

Are other parameters affected or dependent?

Specification of the trace level with rdisp/TRACE

Values allowed

0-10

Examples

• 0: No time stamps are written
• 1: A maximum of one time stamp per second is written (old behavior)
• 5: A maximum of five time stamps per second are written (at least 200ms between the time stamps)
• 10: A maximum of ten time stamps per second are written (at least 100ms between the time stamps)

You May Also Like