Parameter
rdisp/TRACE_RESOLUTION
Short text
Maximum number of time stamps in trace file per second
Parameter Description
You can use this parameter to control the frequency of the time stamp in the trace files. It specifies how many times per second a time stamp is to be written. The default value for this parameter is 1, which means that there is (at least) one second between the time stamps. If the parameter has the value 10, there is (at least) 100ms between the time stamps.
The value 0 deactivates the writing of time stamps.
With a parameter value > 0, the milliseconds of the time stamp are displayed in the following format:
“Fri Sep 3 14:47:54:433 2004”
Application Area
System
Default Value
1
Who is permitted to make changes?
Customer
Operating System Restrictions
None
Database System Restrictions
None
Are other parameters affected or dependent?
Specification of the trace level with rdisp/TRACE
Values allowed
0-10
Examples
• 0: No time stamps are written
• 1: A maximum of one time stamp per second is written (old behavior)
• 5: A maximum of five time stamps per second are written (at least 200ms between the time stamps)
• 10: A maximum of ten time stamps per second are written (at least 100ms between the time stamps)