SFW5: No Further Inconsistency Objects Exist in Outstanding Tasks

If Display Outstanding Tasks in SFW5 reports that no further inconsistency objects exist, do not interpret the message as proof that every intended business function is active. Check the activation job and current status separately.

What to check

Open SFW5 in display mode. Compare the current and planned status of the relevant business functions and review the Switch Framework logs. Use SM37 to check the activation job and ST22 or SM21 for errors around its execution. Compare the affected system with the approved activation plan.

SFW5 business function display from ITSITI
SFW5 business function display from ITSITI

Validation and precautions

If the logs are clean and the intended status is correct, no repair may be required. Do not activate extra business functions to clear an informational message. Many switch activations cannot be reversed easily, so any further action requires functional approval and an appropriate recovery plan.