The generated RFC callback positive list is based on recorded callback events, not a complete inventory of every function that might be called in the future.
What to check
In SM59, identify the destination and inspect the callback list generation results. Compare the relevant Security Audit Log events and time window, using SM20 or the release-specific audit reader. Check whether the callback was actually triggered, whether it was logged and which destination was used. An event outside the available audit history cannot be recovered by list generation alone.
Validation and precautions
Repeat representative business scenarios in a controlled environment with security-approved logging. Review the generated entries before activating them. Do not disable callback enforcement or allow every function simply to make a connection work.
Reference
SAP Note: 3774002