SMQS: Checking Workflow RFC Destination Registration

If a workflow background RFC is not processing, check whether the intended destination is registered with the outbound scheduler before restarting it.

What to check

Log on to the affected client and open SMQS. Find the workflow-related destination and inspect its registration type, status and connection limits. Compare the actual destination with the workflow configuration and SM59. Check SMQ1 and SM58 for pending entries and their error messages, rather than relying on registration status alone.

SMQS registration categories from the existing ITSITI guide
SMQS registration categories from the existing ITSITI guide

Validation and precautions

If you need to establish when registration changed, check the available scheduler and administration logs, security audit records and approved change history. A current registration entry is not a complete historical log. Do not deregister a productive destination or delete queued LUWs just to reproduce the issue.

Reference

SAP Note: 3767598

SAP Help: Documentation