If an SAP workflow no longer starts when a business event is raised, verify the event type linkage before changing workflow definitions or restarting the system.
Check the current linkage
- Open SWE2 or SWETYPV and locate the relevant object or class, event and receiver type.
- Check whether the linkage is active, whether the expected receiver is assigned and whether the configuration belongs to the affected client.
- Review the workflow and event logs for the relevant execution. Use event tracing only when required, and turn off additional tracing after collecting evidence.
Investigate historical changes
Where table change logging was enabled for the relevant configuration table, SCU3 may help establish when an entry changed. Determine the actual table or view in the installed release first. Logging must have been active at the time of the change; a missing log is not proof that no change occurred. Compare with transport history and approved change records.
Do not activate an unfamiliar linkage without functional approval, because this may initiate additional workflows. Validate the expected event and receiver in a controlled test.
SAP Help: Useful Transactions in SAP Workflow
SAP Help: Settings for Workflow
SAP Note: 3718372 (related topic).