Parameter
snc/r3int_rfc_secure
Short text
Use SNC for initiating internal RFC communications
Parameter Description
This parameter controls whether RFCs that go to the same SAP system via internal destinations are secured with SNC. Due to possible performance problems you should declare whether this is necessary because the same level of security can be achieved by other measures too. See also the discussion of this parameter in the security guide for system administrators.
Application Area
SNC
Parameter Unit
Character value
Default Value
0 (internal RFC connections without SNC)
Who is permitted to make changes?
Customer
Operating System Restrictions
None
Database System Restrictions
None
Are other parameters affected or dependent?
snc/enable – Activation of the SNC module (Secure Network Communication)
snc/r3int_rfc_qop – protection level for internal RFCs with SNC
snc/accept_insecure_rfc – General setting for acceptance of insecure RFCs
snc/accept_insecure_r3int_rfc – accepts insecure internal RFCs
Values allowed
0 (internal RFC are started without SNC)
1 (internal RFC are started with SNC)