Parameter
snc/accept_insecure_cpic
Short text
Accept insecure incoming CPIC connections on an SNC-enabled application server
Parameter Description
By default, after the Secure Network Communication (SNC) module is activated, an SAP application server rejects all incoming conventional (non SNC-secured) CPIC connections from external C programs or SAP systems.
If you also want to continue to accept insecure CPIC connections (for example, from old CPIC programs or SAP systems without SNC), you need to configure that using this switch.
Application Area
SNC
Parameter Unit
Character value
Default Value
0 (only secure connections are possible)
Who is permitted to make changes?
Customer
Operating System Restrictions
None
Database System Restrictions
None
Are other parameters affected or dependent?
snc/enable – Activation of the SNC module (Secure Network Communication)
Values allowed
0 insecure connections not accepted
1 insecure connection accepted
U insecure connections accepted, if permitted for the user (indicator in user master record)