zdate/DSTswitch_contloctime

Parameter

zdate/DSTswitch_contloctime

Short text

Activates/deactivates “continuous” system time

Parameter Description

When transferring from summer to winter time, an hour takes place twice. The SAP system can only run for this time as a whole or in part under certain conditions. If it is running, this profile parameter specifies how the system time (SY-UDATUM, SY-TUZEIT) behaves. If the parameter is set to ‘off’, the ‘doubled hour’ is also displayed twice. If the parameter is set to ‘on’, the doubled hour is ‘expanded’, so that no doubled times can arise, that is, for example:

off: 2:00, 2:30, 2:00, 2:30, 3:00.
on : 2:00, 2:15, 2:30, 2:45, 3:00

NOTE: This profile parameter must always consistently have the same value on all servers. If it is changed dynamically, it must be changed on all servers simultaneously.

Application Area

System

Parameter Unit

Default Value

on

Who is permitted to make changes?

System administrator

Operating System Restrictions

None

Database System Restrictions

None

Are other parameters affected or dependent?

None

Values allowed

on / off

You May Also Like

Leave a Reply?